dcmri.flux_nscomp#
- dcmri.flux_nscomp(J, T, t=None, dt=1.0)[source]#
Indicator flux out of a non-stationary compartment.
See section Non-stationary compartment for more detail.
- Parameters:
J (array_like) – the indicator flux entering the compartment.
T (array_like) – array with the mean transit time as a function of time, with the same length as J. Only finite and strictly positive values are allowed.
t (array_like, optional) – the time points of the indicator flux J, in the same units as T. If t=None, the time points are assumed to be uniformly spaced with spacing dt. Defaults to None.
dt (float, optional) – spacing between time points for uniformly spaced time points, in the same units as T. This parameter is ignored if t is explicity provided. Defaults to 1.0.
- Returns:
outflux as a 1D array.
- Return type:
See also
Example
>>> import dcmri as dc >>> t = [0,5,15,30,60] >>> J = [1,2,3,3,2] >>> T = [1,2,3,4,5] >>> dc.flux_nscomp(J, T, t) array([0. , 1.54942844, 2.65376974, 2.88280904, 2.05727851])